WARNING
Installation must be done by an electrician qualified
in the installation of control systems for heating
equipment.
Improper installation, adjustment, alteration, service
or maintenance can result in death, injury or property
damage. Read the Installation and Operation Manual
thoroughly before installing or servicing this
equipment.
Installer
Please take the time to read and understand
these instructions prior to any installation.
Installer must give a copy of this manual to the owner.
Owner
Keep this manual in a safe place in order to provide
your serviceman with necessary information.
Roberts-Gordon LLC
1250 William Street
P.O . B o x 44
Buffalo, New York 14240-0044
Telephone: 716.852.4400
Fax: 716.852.0854
Toll Free: 800.828.7450
www.rg-inc.com
© 2008 Roberts-Gordon LLC
Quality in Any Language™
ROBERTS GORDON
®
UltraVac
Controls for
Modulating
CORAYVAC
®
Infrared Heating
Systems
Installation Manual
P/N 10081601NA Rev F 10/08
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - UltraVac

WARNINGInstallation must be done by an electrician qualifiedin the installation of control systems for heatingequipment.Improper installation, adjustm

Page 2

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL4 URVCCR: ULTRAVAC™ Central Controller with RS-485 ConverterRS-485 Converter Package (P/N 1008

Page 3 - Roberts-Gordon LLC

SECTION 1: INTRODUCTION51. 6 Sa f et yYour Safety is Important to Us!This symbol is used throughout the manual to notify you of possible fire, electr

Page 4

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL6 FIGURE 1: Example Site LayoutNOTE: Conceptual drawing, not to scale. Venting not shown.Zone

Page 5 - TABLE OF FIGURES

SECTION 2: SPECIFICATIONS7SECTION 2: SPECIFICATIONS2.1 ROBERTS GORDON® ULTRAVAC™ Controller2.1.1 EnclosureStandard EnclosureConstruction: 16 gauge pai

Page 6

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL8 FIGURE 2: ROBERTS GORDON® ULTRAVAC™ Controller Specifications+-1+-2+-4+-3+-5+-6+-7+-8+- +-RE

Page 7

SECTION 2: SPECIFICATIONS92.3 Variable Frequency Drive (VFD)2.3.1 EnclosureStandard ModelsConstruction: 14 gauge painted steel, mountingpanel included

Page 8

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL10 FIGURE 3: Variable Frequency Drive Components (Factory pre-wiring shown)M16/12.PM16/12.PPow

Page 9

SECTION 3: INSTALLATION11SECTION 3: INSTALLATIONInstallation of the ROBERTS GORDON® ULTRAVAC™ Controller and the associated external electrical wiring

Page 10 - ROBERTS GORDON

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL12 3.3 Cable Requirements:3.3.1 Line Power Supply:As per individual building specification for

Page 11 - SECTION 1: INTRODUCTION

SECTION 3: INSTALLATION133.4 Electrical Installation Requirements3.4.1 The enclosure must be supplied from a local fused isolator rated for a total am

Page 13 - SECTION 2: SPECIFICATIONS

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL14 3.7 Indoor Sensor PlacementThe sensor measures the air temperature in the building. It is i

Page 14 - Controller Enclosure

SECTION 4: TYPICAL EXTERNAL DIAGRAMS15SECTION 4: TYPICAL EXTERNAL DIAGRAMSFIGURE 10: Central Controller Communication Equalization Wiring+-1+-2+-4+-3+

Page 15

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL16 FIGURE 11: ROBERTS GORDON® ULTRAVAC™ Central Controller External Wiring+-12435678+-+-REF24V

Page 16 - L2/NL1 B-PE

SECTION 4: TYPICAL EXTERNAL DIAGRAMS17ROBERTS GORDON® ULTRAVAC™ Central Controller External Wiring (continued)for 115 V and 230 V input VFD models.VFD

Page 17 - SECTION 3: INSTALLATION

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL18 FIGURE 12: ROBERTS GORDON® ULTRAVAC™ Satellite Controller External WiringADDRESSRESET10VDC4

Page 18

SECTION 4: TYPICAL EXTERNAL DIAGRAMS19ROBERTS GORDON® ULTRAVAC™ Satellite Controller External Wiring (continued)L1L2T1L1L2L1L2L1L2L1L2L1L2L1L2Zone 3Bu

Page 19

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL20 SECTION 5: COMMUNICATIONSOne ROBERTS GORDON® ULTRAVAC™ Controller per building (called the

Page 20 - SEN SET O/R

SECTION 5: COMMUNICATIONS215.2 RS-485 Converter for Central ControllerFor remote on-site viewing of system status and settings of any controller, use

Page 21 - Shrinkwrap

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL22 5.3 TCP/IP Communication ModuleFor remote on-site viewing of system status and settings

Page 22 - FIGURE 11: ROBERTS GORDON

SECTION 5: COMMUNICATIONS23FIGURE 16: TCP/IP Communication Module Wiring+-1+-2+-4+-3+-5+-6+-7+-8+- +-REFRS485 COMMREF+-1+-2+-3+-4METER INPUTSUNIVERSAL

Page 23

© 2008 Roberts-Gordon LLCAll rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any

Page 24 - FIGURE 12: ROBERTS GORDON

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL24 5.4 Direct ConnectFor local viewing of system status and settings of any controller, a port

Page 25

SECTION 5: COMMUNICATIONS255.5 Communications Between Multiple ROBERTS GORDON® ULTRAVAC™ ControllersIf more than one ROBERTS GORDON® ULTRA-VAC™ Contro

Page 26 - Modem Chip 10080142

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL26 5.5.1 RepeaterIf the RS-485 communications wire length is above 4000', a repeater must

Page 27 - Ground Shield

SECTION 6: VARIABLE FREQUENCY DRIVE PROGRAMMING27SECTION 6: VARIABLE FREQUENCY DRIVE PROGRAMMING6.1 VFD Parameter Settings For Use With ROBERTS GORDON

Page 28

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL28 the password must be entered in order to access the parameters again.6.2 Altering VFD Param

Page 29 - Direct Port

SECTION 7: COMMISSIONING THE CORAYVAC® SYSTEM29SECTION 7: COMMISSIONING THE CORAYVAC® SYSTEMNOTE: The ROBERTS GORDON® ULTRAVAC™ software must be insta

Page 30

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL30 FIGURE 20: End Vent Vacuum6543210123456ManometerInsert tubingabout 6" (15cm)into end v

Page 31 - Do Not Ground

SECTION 7: COMMISSIONING THE CORAYVAC® SYSTEM31FIGURE 21: Possible Damper Couplings’ LocationsDamper CouplingDamperNOTE: Damper settingwill varyZone 1

Page 32 - Repeater 10080445

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL32 Step 7.1.3 After setting end vent vacuums between 2.5" wc and 3.0" wc, while all

Page 33

SECTION 8: REPLACEMENT PARTS33SECTION 8: REPLACEMENT PARTS8.1 ROBERTS GORDON® ULTRAVAC™ Controller Replacement PartsCaution: Use only genuine ROBERTS

Page 35 - OMMISSIONING THE CORAYVAC

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL34 8.2 Variable Frequency Drive Replacement PartsCaution: Use only genuine ROBERTS GORDON® rep

Page 36 - FIGURE 20: End Vent Vacuum

SECTION 8: REPLACEMENT PARTS358.3 Replacement Parts Instructions8.3.1 Plug-In RelayTo replace the plug-in relay, turn off 120 V power to the relay boa

Page 37

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL36 8.3.6 Variable Frequency Drive 25 A or 10 A FuseTo replace a fuse, turn off input power to

Page 38

SECTION 9: TROUBLESHOOTING37SECTION 9: TROUBLESHOOTINGFIGURE 24: Troubleshooting Flow ChartContact yourROBERTS GORDON® Independent Distributor.On the

Page 39 - SECTION 8: REPLACEMENT PARTS

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL38 Troubleshooting Flow Chart (continued)Replace rotary disconnect base block.Is there power (

Page 40

SECTION 9: TROUBLESHOOTING39Troubleshooting Flow Chart (continued)Adjust system for proper vacuum at the end vent. See Commissioning of the CRV System

Page 41

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL40 Troubleshooting Flow Chart (continued)Consult wiring instructions in 200 Series Pump Manual

Page 42

SECTION 10: THE ROBERTS GORDON® ULTRAVAC™ LIMITED WARRANTY41SECTION 10: THE ROBERTS GORDON® ULTRAVAC™ LIMITED WARRANTYROBERTS-GORDON WILL PAY FOR:With

Page 44

TABLE OF FIGURESFigure 1: Example Site Layout ...6Figure 2: ROBERTS GORDON® ULTRAVAC™ Controller Specif

Page 46

SECTION 1: INTRODUCTION1SECTION 1: INTRODUCTION1.1 What is ROBERTS GORDON® ULTRAVAC™?The ROBERTS GORDON® ULTRAVAC™ is a micro- processor based control

Page 47 - ULTRAVAC™ LIMITED WARRANTY

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL2 1.5 Carton ContentsURVSC: ULTRAVAC™ Satellite Controller URVCCL: ULTRAVAC™ Central Contro

Page 48

SECTION 1: INTRODUCTION3URVCCM: ULTRAVAC™ Central Controller with ModemULTRAVAC™ Software (P/N 10080421)ULTRAVAC™ Software Manual (P/N 10081600NA)ULTR

Comments to this Manuals

No comments